Maxx GmbH

Model TP5 C with active cooling Housing: Signal inputs: 2 x analogue: 0/4–20 mA, max. working resistance 500 Ohm 8 x digital (Flow, Event, 1 x free programmable) Sampling method: Suction height: 6,5 m (at 1000 hPa) Pumping speed: > 0,5 ms at suction height up to 5 m (at 1000 hPa) Suction hose: PVC, L = 5 m, ID = 10 mm Sampling modes: Time, flow, event-related and manual sample Bottle variants: 1 x 10 L; 1 x 25 L, 2 x 13 L; 4 x 5 L; 16 x 1 L PE incl. freezer packs 24 x 1 L PE (standard version) Overall dimensions: 1.028 x 550 x 468 mm (hxwxd)/Insulating box active Weight: approx. 40 kg; Isobox with active cooling (24 x 1 L) Ambient temperature: 0° to +50° C Sample temperature: 0° to +40° C Standards: PE/PC (GF10) Interface: Signal outputs: 8 digital outputs, 1x of them as collective malfunction message (max. hose length 20 m) Vacuum 20–350 ml Option: variable flow-proportional sampling CE, sampling according to ISO 5667-10, EN 16479 Doublewalled, insulated lower part MiniUSB, optional: Ethernet RJ45, SDI-12 Thermostatic control: compressor cooling (12 V/115 V/230 V) Microprocessor control, foil keypad, back lit display Option: with PC software or LAN/GPRS/Web communication (2 year ring memory FIFO at 1 min interval) 12 freely programmable programs, user-friendly software Control: Power supply: Sampler 12 V/ active box 230 V–50 Hz/115 V–60 Hz/12 V battery 10 Ah battery/charger IP44 or IP67 Technical data at a glance Innovation made in Germany Impulse length 60 ms, switching level 7–24 V Programming:

RkJQdWJsaXNoZXIy MjQxNTg=